Product details
PVC Tee Fitting: Branch and Combine Pipelines with One Connection
![]() | ![]() |
![]() | ![]() |
| A PVC tee fitting (also called PVC equal tee or PVC T-fitting) splits one pipeline into two directions or merges two lines into one through a single T-shaped connection. With three identical socket openings of the same diameter, it is the most widely used branch fitting in water supply, irrigation, and drainage systems worldwide.Daecheon Pipe manufactures PVC tee fittings from 100% virgin PVC-U resin with organotin stabilizers— never recycled material. Our fittings comply with ASTM D2466, BS EN ISO 1452, and IS 4985, serving contractors across Africa, Southeast Asia, and South America. |
Product FeaturesThree Equal Socket OpeningsUnlike reducing tees that have different diameters, an equal PVC tee has three identical solvent-weld sockets. This means you can branch a main line at 90 degrees without changing pipe size—maintaining consistent flow capacity through both the run and the branch. Simply apply cement, insert, and hold. No threading or gaskets needed. Precision Injection-Molded for Leak-Free JointsEach socket is formed by precision injection molding with tight dimensional tolerances. This ensures a snug interference fit with the pipe before cementing, which creates a permanent solvent-weld joint as strong as the pipe itself. Properly cemented PVC tee joints do not leak, loosen, or degrade over time —unlike threaded metal connections that require Teflon tape and still may seep. |
![]() | ![]() |
Corrosion and Chemical ResistancePVC-U material resists acids, alkalis, salts, and most chemicals found in water supply and industrial systems. Unlike cast iron or galvanized steel tee fittings that rust internally and restrict flow, PVC tees maintain smooth internal walls for decades. This chemical resistance also makes them suitable for certain chemical processing and laboratory drainage applications. Lightweight and Cost-EffectiveA PVC tee fitting weighs a fraction of its metal counterpart. A 110mm PVC tee weighs under 400g versus several kilograms for cast iron. Lower weight means cheaper shipping, easier handling on site, and faster installation —especially on large projects with dozens or hundreds of branch connections. The material cost is also significantly lower than copper or stainless steel alternatives |
![]() | ![]() |
100% Virgin PVC-U with Organotin StabilizersWe use only virgin PVC-U resin with organotin stabilizers: - Non-toxic formulation safe for potable water contact |
Available Sizes and Standards| Size | Standard | Working Pressure | Socket Depth | Need a different diameter at the branch? See our PVC reducing tee fittings for branch connections with size reduction. Custom sizes, wall thicknesses (Schedule 40/80), and colors are available upon request. |
![]() | ![]() |
PVC Equal Tee vs Reducing TeeUnderstanding the difference helps you choose the right fitting for each connection point: PVC Equal Tee (this product): All three openings share the same diameter. Use it when the branch line continues at the same pipe size as the main run. Example: a 63mm main line branching into a 63mm side line. PVC Reducing Tee: The branch opening is smaller than the main run openings. Use it when the branch serves a smaller line—such as a 63mm main with a 32mm branch for a tap connection. This eliminates the need for a separate reducing coupling on the branch. For most residential water supply systems, equal tees are used on the main distribution lines, while reducing tees connect smaller service branches. When you also need to change direction, use elbows in combination with tees. |
![]() | ![]() |
Installation GuideStep 1: Cut and PrepareCut the PVC pipe square using a fine-tooth saw or pipe cutter. Remove all burrs with a deburring tool or utility knife. Chamfer the pipe end at approximately 15° to prevent cement from being pushed out during insertion. Wipe the pipe exterior and the tee socket interior with a clean, dry cloth to remove dust and moisture. Step 2: Dry Fit CheckInsert the pipe into the tee socket without cement. The pipe should enter 1/3 to 2/3 of the socket depth with moderate resistance. If it slides in too easily or cannot enter, verify that both pipe and fitting sizes match and conform to the same standard. Step 3: Apply Solvent CementApply an even coat of PVC solvent cement to the pipe exterior and the socket interior. Insert the pipe straight into the socket with a firm, quarter-turn (90°) rotation to distribute the cement evenly. Hold the joint for 15–30 seconds until initial set. Wipe off any excess cement immediately with a cloth. Repeat for all three connections. Step 4: Cure and Pressure TestAllow the solvent cement to cure fully before pressurizing the system —minimum 24 hours for sizes above 50mm. Conduct a hydrostatic test at 1.5× working pressure to confirm all joints are leak-free. A properly cemented PVC tee joint is permanent and will not separate under normal operating pressure. |
![]() | ![]() |
Common ApplicationsWater Supply Distribution: Branching a main supply line to serve multiple floors, units, or zones. The equal tee maintains full flow capacity at the branch, ensuring consistent water pressure downstream. This is the most common application in residential and commercial plumbing. Irrigation Systems: Splitting main irrigation lines into lateral feeds. PVC tees handle continuous water pressure (PN10) and resist the UV exposure and soil chemicals common in agricultural settings. Their smooth interiors minimize pressure loss at branch points. Industrial Piping: Creating branch connections in chemical processing, water treatment, and cooling systems. PVC-U resists a wide range of industrial chemicals and operates reliably at temperatures up to 60°C. No corrosion means no contamination of process fluids. Swimming Pool and Spa Plumbing: Routing water to pumps, filters, and return jets. PVC tees are the standard branch fitting in pool piping because they resist chlorine, pool chemicals, and constant water pressure without degrading. |
Technical Tips for Tee InstallationSupport the Branch: When a tee creates a branch line, the branch pipe applies leverage at the connection point. Install a pipe support or hanger within 300mm of the tee on the branch side to prevent stress on the solvent-weld joint. Flow Direction Matters: In pressure systems, position the tee so that flow enters through the run (the straight-through path) and exits through the branch. This orientation minimizes pressure loss. Reverse flow (entering through the branch) creates more turbulence and reduces efficiency. Spacing Between Fittings: Avoid installing two tees directly next to each other. Maintain at least 6× pipe diameter between fittings to allow flow to stabilize. For example, on a 50mm pipe, allow at least 300mm between two branch connections. Pressure De-Rating at Branches: A tee fitting inherently creates a weak point in a pressurized line because the pipe wall is interrupted. For systems operating near PN10, consider using 90° elbows with separate couplings for critical high-pressure branch points instead. |
Why Choose Daecheon Pipe- Est. 2001, 20+ years of PVC/PPR fitting manufacturing |
Frequently Asked QuestionsWhat is the difference between a PVC equal tee and a reducing tee?An equal tee has three openings of the same diameter. A reducing tee has a smaller branch opening—typically one or two sizes smaller than the main run. Choose an equal tee when the branch pipe is the same size as the main line, and a reducing tee when the branch serves a smaller pipe. Can PVC tee fittings be used for hot water?PVC-U tee fittings are rated for continuous use up to 60°C. For hot water above 60°C, use CPVC fittings rated to 95°C instead. Always verify that the fitting material matches the operating temperature of your system. Do I need to use primer before solvent cement?Yes. For pipes 50mm and above, applying PVC primer before cement is strongly recommended. Primer softens the pipe surface for better chemical bonding and is required by most plumbing codes. For smaller sizes (20–40mm), some one-step cements combine primer and cement—check local code requirements. Can PVC tees be buried underground?Yes. PVC tees are commonly used in underground water supply and irrigation systems. Ensure proper bedding (sand or fine soil, no sharp rocks), and provide thrust blocking at tee connections to prevent joint separation from water hammer and pressure thrust. Consult the Uni-Bell PVC Pipe Association for buried installation guidelines. |
Get a QuoteNeed PVC tee fittings for your project? Contact Daecheon Pipe for competitive pricing, fast delivery, and custom specifications. 📞 WhatsApp: +86 139 5702 1987 Daecheon Pipe — Quzhou Dachuan Plastic Co., Ltd. |